Wirelynx TR2101 PLC Receivers

Wirelynx R-2101 PLC Receivers are located at remote points on the powerline within a building or electrical service on the same phase as a TR2001 transmitter.  When the Receiver receives a signal over the powerline from a TR2001 transmitter of the same channel, the relay contacts switch from the "normal" position to the "energized" position and a green LED lights.  When the powerline signal stops, the relay switches back to the normal position and the green LED goes out.  As many Receivers as desired can be connected to the same powerline and will receive signals from one TR2001 Transmitter of the same channel.  Receivers may be placed on a circuit of a different voltage within the building as long as the receiver is on the same distribution transformer.  This is accomplished by using the Wirelynx Model TR2201 Transformer Jumper which couples signals across transformers.

TR2101 Receivers have been designed to ignore electrical noise such as SCR light dimmers, motors, motor controllers, electronic ballasts, arc welders, power surges, broadcast band radio transmissions and other brands of powerline carrier systems.  This is done by circuit techniques such as narrow band crystal tuning, signal limiting and integrating detectors.  Transmitters will not normally cause interference with radio or TV receivers and conform to FCC rule part 15.  All components contain internal protection against damage from normal power surges and typical, but not direct, lightning strikes.

Wirelynx TR2101 PLC Receivers are available in several different voltages and output types.  See the table below for specific model information.

Product Selection: 
1.  Select the voltage that will power the TR2101 receiver.  This is generally the same voltage as the transmitter.  When the receiver "hears" its carrier signal, its relay is energized.
2.  Select the output capacity: A.) "Low Power" - The switched voltage is limited to 250VAC/28VDC and the relay contacts' current switching capacity is three (3) Amps; or B.) "High Power" - The switched voltage is limited to 277VAC/28VDC and the relay contacts' current switching capacity is 30 Amps.  In both cases, the receivers remain powered all the time. Caution: DO NOT attempt to switch 480VAC with the outputs of these receivers.  Their absolute maximum ratings are shown.
3.  Select the channel, either 5 or 7.  The receiver's channel number must match the channel number of the transmitter that you want it to respond to.

Select the appropriate model from the table below:
Wirelynx TR2101 Receivers
Model # Part # Line Voltage Output Dry Contact Ratings Channel
R-1 TR2101-00001 24*,120,208-277VAC 3Amp@250V 5
R-2 TR2101-00002 24*,120,208-277VAC 3Amp@250V 7
R-3 TR2101-00003 480VAC 3Amp@250V 5
R-4 TR2101-00004 480VAC 3Amp@250V 7
R-5 TR2101-00005 24*,208-277VAC 30Amp@277V 5
R-6 TR2101-00006 24*,208-277VAC 30Amp@277V 7
R-7 TR2101-00007 480VAC 30Amp@277V 5
R-8 TR2101-00008 480VAC 30Amp@277V 7

* 24VAC by special order only.



Specifications

Model R-2101 Powerline Carrier Receiver
Part Number R2101-x

Voltage to power Receiver:                    24, 120, 208 to 277, 480VAC (model dependent)
Current to power Receiver:                    .01 Amp @ 24VAC - 480VAC
Isolated Form C Contacts:                     3 Amp at 250VAC/28VDC
                                                             30Amp at 277VAC/28VDC
Mounting: Mount with ½” conduit chase nipple supplied or mounting bracket.

Go to TR2001 Transmitters

Call Brayden Automation Corp. for additional information and pricing. 